Wirestam R;Larsen VA;Stubgaard M;Thomsen C;Vikhoff B;Larsson HB;Stahlberg F;Henriksen O
Deuterium MR spectroscopy at 4.7 T. Quantification of tumour and subcutaneous tissue blood flow in animal models
Acta Radiol 1995, 36(1), , 85-91
Deuterium MR spectroscopy was used for the determination of tissue blood flow (TBF). The tracer D2O was injected into the tissue of interest, and tracer washout was followed using a 4.7 T spectroscopy/imaging unit. Normal subcutaneous tissue in rats was studied, as well as tissue influenced by vasoactive agents (papaverine and adrenaline). The vasoactive agents introduced changes of 40% in TBF, compared with normal tissue. Normal tissue measurements were repeated using various D2O injection volumes (5-400 microliters). The injection volume 5 microliters gave TBF 11.7 +/- 2.0 ml/100 g.min (mean +/- 1 SD). This value was 40% higher than corresponding values observed at larger injection volumes (200-400 microliters). This injection volume effect is probably partly due to a capillary dilution caused by tracer administration, and partly related to the non-physiological deuterium signal decrease observed in dead rats. Blood flow measurements in human colon tumours implanted in nude mice showed a rather poor reproducibility, not improved by the use of a multiple site injection technique